Mon-Fri 09:00-18:00
EXON IMPEX Modern technologies for education and business
KRONT UDE-2 endoscopic disinfection unit
Эндоскопическое оборудование

KRONT UDE-2 endoscopic disinfection unit

Endoscopic disinfection unit UDE-2-KRONT Designed for high-level disinfection (TLD) flexible endoscopes for non-sterile endoscopic interventions. The installation allows you to increase the productivity of medical personnel, reduce labor costs and ensure high safety and efficiency of endoscope processing. The installation is a trolley with an installed endoscope processing device ENDODESIS-"CRONT". The trolley consists of a frame structure with a bathtub with a lid for immersing the endoscope, shelves, a tray and KDS-KRONT containers placed on it. The bath is made of impact-resistant polystyrene or ABS plastic and has streamlined contours to avoid critical bending of the endoscope during processing and allows the placement of any models of flexible endoscopes. The bath is equipped with a device for draining waste solutions. The drainage device is made in the form of a flexible tube with a locking tip. The tray and hanging shelves are made of polypropylene. Main advantages: Compatible with endoscopes from different manufacturers. Processing of all endoscope channels simultaneously (up to 5 channels). Automatic control of processing stage time. Sound and visual indication of the end of the processing stage. Streamlined bath contours to prevent critical bending of the endoscope during processing. Processing of flexible endoscopes in the installation is carried out in accordance with the methodological instructions “MU 3.1.3798-22. Prevention of infectious diseases. Ensuring epidemiological safety of non-sterile endoscopic interventions on the gastrointestinal tract and respiratory tract", other current documents that reflect issues processing of endoscopes, as well as instructions for the use of specific disinfectants. The adapters and devices included in the delivery kit are designed to connect flexible endoscopes manufactured by LOMO, Olympus and Pentax. To connect endoscopes from other manufacturers, use the accessories included in the scope of delivery of the endoscopes. Accessories: Pallet and hanging shelves made of polypropylene. For the convenience of sanitary processing, they are self-fixing and easily removable. Polymer container container (working volume: 0.2±0.05 l) KDS-0.2 with a perforated tray and lid is designed for processing endoscopic instruments and accessories (valves, caps and plugs). Overall dimensions (Diameter × Height), mm: Ø96 × 72 (without handle). Quantity – 2 pcs. Polymer container container (working volume: 1±0.2 l) KDS-1 with a perforated tray and lid is designed for processing endoscopic instruments and accessories (valves, caps and plugs). Overall dimensions (L × W × H): 280 × 155 × 105 mm. Quantity – 1 pc. Polymer container container (working volume: 10±1.6 l) KDS-10 with a perforated tray and lid is designed for collecting and storing reusable solutions and rinsing bronchoscopes with sterile, boiled or purified water using antibacterial filters. Overall container size (L × W × H): 450 × 325 × 205 mm. Quantity – 2 pcs. A set of devices for connecting endoscopes (adapters and devices) are designed to connect various models of Olympus, Pentax and LOMO endoscopes. The principle of operation of the installation is to fill and constantly pump through all channels of the endoscope a solution of a disinfectant, water for rinsing, air and alcohol to dry the channels through adapters and flushing tubes for the time specified in instructions for using a specific product with the ability to control the temperature of the solution. It is possible to process several channels simultaneously - up to 5 (aspiration, instrumental, water, air and one additional channel). The device pumps working solutions at a constant speed and pressure, eliminating the possibility of retaining air bubbles in the channels, thereby ensuring high efficiency in processing endoscope channels. The device allows you to automatically provide the required time endoscope processing and temperature control of the working solution. The following are connected to the device: - an intake line for collecting working solutions from the washing bath; - pressure line for connection to the inputs of endoscope channels. The pressure line is equipped with adapters for connecting to the inputs of endoscope channels and a safety valve to prevent excess pressure from occurring in the channels. Filtration of the disinfectant solution supplied to the endoscope channels is ensured by a two-stage filter, consisting of a pre-filter and a fine mesh filter. The filter meshes are made of stainless steel with cell sizes of 0.1 and 0.5 mm. To remove residual disinfectant after HLD, the endoscope must be transferred for rinsing to a washing bath / container with water of regulated microbiological quality. The surfaces of the installation are resistant to treatment with disinfectant solutions by wiping. Easy to transport thanks to 4 swivel castors Ø75 mm. Manba: https://www.nv-lab.ru/catalog_info.php?ID=9845

Price on request
  • Parameter: Value
  • Working load, kg: 49 (per bath – 22 kg, per tray – 20 kg, per two shelves – 5.5 kg, per Endodez holder – 1.5 kg)
  • Internal dimensions of the bath, mm: (560 × 420 × 160)±10
  • Bath volume, l
  • - worker;
  • - maximum: 14;
  • 20±2
  • Overall dimensions, mm, no more
  • - installations (L × W × H);
  • - transport packaging: (1070 × 635 × 1235)±25;
  • 930 × 490 × 660
  • Weight, kg, no more
  • - installations;
  • - transport packaging: 23;
  • 25