Mon-Fri 09:00-18:00
EXON IMPEX Modern technologies for education and business
Steam sterilizer VKA-75 PZ semi-automatic
Паровые стерилизаторы (Автоклавы)

Steam sterilizer VKA-75 PZ semi-automatic

Steam sterilizer VKA-75 PZ semi-automatic Designed for sterilization with saturated water steam under excess pressure of medical products made of metals (surgical instruments, etc.); glass (dishes, etc.); rubber (surgical gloves, etc.); plastics; dressings and ligature suture materials; products made of textile materials (surgical linen, etc.), medicinal solutions, hermetically sealed and unsealed in glass containers with a volume of up to 1000 ml, the effect of steam on which does not cause a change in their functional properties. Drying of the sterilized material is carried out under a vacuum, which is created using an ejector. The sterilizer has a reusable filter for bacterial purification of air admitted into the sterilization chamber after vacuum drying. The number of sterilization boxes of type KSKF-18, simultaneously loaded into the chamber – 3 pcs. (supplied by separate order). Scope of application: The sterilizer is intended for use in central sterilization departments, sterilization operating rooms, hospital wards, pharmacies, laboratories. Benefits: the sterilization chamber and steam generator are made of stainless steel and are a single welded structure; The drain hole of the chamber has a filter to protect hydraulic equipment from debris; all elements of the sterilizer vessel, except for seals, pipelines and fittings, are made of corrosion-resistant steel, the inner surface of the chamber is processed by electrochemical polishing; ease of operation. All elements of the sterilizer comply with GOST 31598: - resistant to steam and condensate; - do not affect the quality of steam; - do not emit toxic substances in concentrations exceeding the maximum permissible concentration (MPC). Manba: https://www.nv-lab.ru/catalog_info.php?ID=728

Price on request
  • Parameter: Value
  • Camera type: round
  • Useful chamber volume, l: 75
  • Maximum operating pressure, MPa: 0.22
  • Pressure maintenance accuracy, MPa: ±0.2
  • Internal dimensions of the chamber (Ø × D), mm: 400 × 658
  • External dimensions (W × D × H), mm: 825 × 522 × 1096
  • Weight, kg: 140
  • Power consumption, kW, no more: 6.5
  • Power, V/Hz: 380/50
  • Specified temperature conditions, °C: 132 °C – 20 min;
  • 120 °C – 45 min;
  • 110 °C – 180 min
  • Sterilizer heating time, min, no more than: 60
  • Maximum temperature deviation in the loaded chamber from the nominal value, °C, no more than: ±2
  • Corrected sound power level, dBA, no more than: 70
  • Continuous operation time per day, h, not less: 16
  • MTBF, cycles, not less: 1000
  • Average service life, years: 10

Solution selection

We will recommend a setup for a classroom, hall or laboratory

The request is saved to the database so a manager can process it later.