Steam sterilizer GKa-100 PZ semi-automatic
Steam sterilizer GKa-100 PZ semi-automatic The semi-automatic steam sterilizer is designed for sterilization with saturated water steam under excess pressure of medical products made of metal, glass, rubber, plastic, dressings and ligature sutures, textile products, medicinal solutions, hermetically sealed and unsealed in glass containers, the effect of steam on which does not cause a change in their functional properties. Horizontal design. Preliminary removal of air from the sterilization chamber carried out using the gravity blowing method. Vacuum drying is carried out using a condenser. The sterilizer has a bacterial air purification filter, entering the sterilization chamber during the pressure equalization stage. The number of KF-18 type sterilization boxes simultaneously loaded into the chamber is 4 pcs. (supplied by separate order). Scope of application: The sterilizer is intended for use in treatment and prophylactic, medical and other institutions. Benefits: economical, simple and easy to use; a door with a central shutter on which three handles are attached; the sterilizer chamber and all main elements are made of corrosion-resistant steel; built-in steam generator; turning off heating elements when the water level in the steam generator decreases; protective device against pressure increase in the steam generator; electronic system for indicating the water level in the sterilizer; The sterilizer is designed to lock the door if there is pressure inside the chamber. All elements of the sterilizer comply with GOST 31598: - resistant to steam and condensate; - do not affect the quality of steam; - do not emit toxic substances in concentrations exceeding the maximum permissible concentration (MPC). Manba: https://www.nv-lab.ru/catalog_info.php?ID=3290
- Parameter: Value
- Camera type: round
- Useful chamber volume, l: 100
- Maximum operating pressure, MPa: 0.22
- Pressure maintenance accuracy, MPa: ±0.2
- Volume of distilled water poured in when starting the sterilizer for the first time, l: 30
- Internal dimensions of the chamber (Ø × D), mm: 400 × 771
- External dimensions (W × D × H), mm: 600 × 1130 × 1400
- Weight, kg: 200±20
- Power consumption, kW, no more: 11
- Power, V/Hz: 380/50
- Specified temperature conditions, °C: 134 °C – 5 min – 0.31 MPa;
- 121 °C – 20 min – 0.21 MPa
- Temperature conditions set at the factory upon separate order, °C: 110 – 135 °C, 5 – 180 min, 0.15 – 0.32 MPa
- Sterilizer heating time, min, no more than: 45
- Maximum temperature deviation in the loaded chamber from the nominal value, °C, no more than: ±2
- Continuous operation time per day, h, not less: 16
- MTBF, cycles, not less: 1000
- Average service life, years: 10