Spectrophotometer PE-5300V
Discontinued from sale, the closest analogue is Spectrophotometer PE-5300VI (Ekokhim) Spectrophotometer PE-5300 V The PE-5300 V spectrophotometer has been produced for many years and is used to perform all photometric methods of quantitative analysis in accordance with the laboratory requirements of any sectors of the national economy of the Russian Federation. The spectrophotometer is used to monitor the composition of water, soil, air in environmental and sanitary-hygienic studies, as well as in the analysis of raw materials, finished products, metals and alloys, chemical products, etc. The device is included in the State Register of Measuring Instruments under No. 58561-14 The actually achieved accuracy in determining the directional transmittance T reaches 0.5% in the range of 0-200%. The device uses filling cuvettes from the KFK-3 and FEC kits. The large cuvette compartment allows you to simultaneously accommodate 3 cuvettes with a working length of 5-100 mm. The plug holders supplied in the kit also allow the use of non-standard or imported cuvettes (12mm width). The informative high-contrast display simultaneously displays the values of optical density A, transmittance T and wavelength λ. The device can be operated without prior training. No commissioning required. The chemical-resistant case with a splash-proof keyboard ensures long service life in aggressive environments. The device is supplied with software for collecting and processing results on a personal computer. Connection to a computer is via USB 2.0 port Periodic verification is carried out by regional bodies of the Center for Medical Management using a verification scheme. The device is stable in its readings, and unlike its analogues, it does not require checking its metrological characteristics during the verification interval. Spectral range, nm from 315 to 1000 Spectral coefficient measurement range directional transmission,% from 0.1 to 99 Directional spectral coefficient reading range transmittance,% from 0 to 200 Range of optical density readings, B from -0.3 to 3.0 Limit of permissible absolute error of the spectrophotometer at measuring directional transmittance coefficients, %: -in the spectral range from 400 to 800 nm ±0.5 - in the rest of the spectral range ±1.0 Error in setting wavelengths, nm, no more ±2.0 Spectral slit width, nm 5 Scattered light level (at λ=340 nm), %, no more 0.3 Overall dimensions (LxWxH), mm 480×360×160 Weight, kg, no more 8 Power consumption, VA, no more 25 Average service life, years 8 MTBF, h, not less 6400 Supply voltage frequency (50±1) Hz, V 220+22-33 Operating conditions - ambient temperature range, ºC from 15 to 30 - range of relative humidity of ambient air (at 25ºС), % not more than 80 - atmospheric pressure range, kPa from 84 to 106 Manba: https://www.nv-lab.ru/catalog_info.php?ID=1132