Mon-Fri 09:00-18:00
EXON IMPEX Modern technologies for education and business
Laboratory ion meter/conductivity meter/oxygen meter Anion-4152
Мультипараметровые приборы

Laboratory ion meter/conductivity meter/oxygen meter Anion-4152

Laboratory ion meter/conductivity meter/oxygen meter Anion-4152 Analyzers of the ANION 4152 series are combined multichannel analyzers and are used to measure: - ion activity (pX); - molar and mass concentration of ions; - EMF of electrode systems (mV); - specific electrical conductivity (mS/cm); - total mineralization in terms of NaCl and other electrolytes (g/l); - oxygen concentration (%, mg/dm3); - water temperature (°C). Specialized device. Designed for the needs of thermal power engineering, as the package includes a flow cell and an oxygen sensor for determining low concentrations of dissolved oxygen in water. An oxygen sensor with increased sensitivity is recommended for use in waters containing dissolved hydrogen in concentrations not exceeding 20 µg/l. Features of ANION-4152: - selection of a unit of measurement of the main parameter convenient for the operator: in potential (mV), рХ (рН), molar (mol/l) and mass (mg/l) concentrations; UEP (μS/cm; mS/cm), salt content (mg/l; g/l); oxygen concentration (%; mg/dm3); - simple and intuitive control of the device; - informative backlit display; - registration, storage and viewing of measurement results and calibration data; - automatic temperature compensation; - real time clock and calendar; - automatic taking of measurement readings by the device and recording them in a notebook (199 groups of measurements) at specified time intervals; - transfer of information to a personal computer, the ability to control the device via a PC via an RS-232C communication channel; - power supply from a network adapter or autonomous; - one potentiometric physical channel; - auto-labeling of the channel with the chemical formula of the element based on the entered molar mass; - semi-automatic calibration with memorization and storage of parameters from 2 to 6 standards; - connector for ISE - BNC; - automatic recalculation of UEP into the degree of mineralization from a list of 30 names of electrolytes; - the device is calibrated using two values ​​of oxygen concentration - 0% and 100%; - the influence of atmospheric pressure is taken into account during calibration and measurements with manual or automatic input of values ​​from the built-in barometric sensor. Manba: https://www.nv-lab.ru/catalog_info.php?ID=6889

Price on request
  • Range: ±2000
  • Resolution: 1
  • Accuracy: ±2
  • Range: -2…14
  • Resolution: 0.01
  • Accuracy: ±0.02
  • Range, °C: 0-60
  • Error, units pH: 0.04
  • Range: 0.0003-10
  • Resolution: 0.0001-0.1
  • Accuracy: ±2%
  • Range: 0.0002-2
  • Resolution: auto selection
  • Accuracy: ±1%
  • Range, °C: 0-50
  • Accuracy: ±1%
  • Range: 0-20 mg/dm3
  • 0-200%
  • Resolution: 0.001 mg/dm3
  • 0.01%
  • Accuracy: from 0 to 2 mg/dm3 ±0.002
  • from 2 to 10 mg/dm3 ±0.1
  • from 10 to 20 mg/dm3 ±0.2
  • from 0 to 20% ±0.2
  • from 20 to 100% ±1
  • Range, °C: 0-50
  • Accuracy: ±0.1 mg/dm3
  • ±1%
  • Range: 0-50
  • Resolution: 0.1
  • Accuracy: ±0.3
  • Range: 84-106
  • Resolution: 0.1
  • Accuracy: ±0.5