Conductivity meter HANNA HI2300-02 (laboratory)
Кондуктометры

Conductivity meter HANNA HI2300-02 (laboratory)

The Hanna HI-2300 measures conductivity, TDS (total dissolved solids), NaCl percentage and temperature. If necessary, the meter can be connected to a computer using the RS232 port, and additional Hanna software allows you to export data and print it. Featuring automatic conductivity and total dissolved solids (TDS) ranges, this instrument can be easily switched to salinity measurements ranging from 0.0 to 400.0% NaCl (seawater salinity). Peculiarities. Automatic Range Selection - For conductivity and TDS measurement modes, based on the solution sample being measured, the HI2300 automatically selects the optimal measurement range to ensure the highest possible accuracy. Automatic Calibration - EC and TDS ranges are automatically calibrated at one point with a choice of six pre-programmed standards. Four-electrode sensor - The HI2300 is equipped with a four-electrode potentiometric conductivity sensor HI76310 with a built-in temperature sensor and platinum sensing elements, which operates over a wide range from 0.00 µS/cm to 500.0 mS/cm *. Temperature compensation - temperature compensation can be either automatic (ATS) or manual (MTC) in the range from -20.0 to 120.0 °C. In addition, it can be disabled for actual conductivity or TDS measurements. The temperature compensation coefficient, also known as β, is adjustable from 0.00 to 6.00%/°C. Adjustable TDS Conversion Factor - The conversion factor from conductivity readings to total dissolved solids depends on the type of sample being measured. To obtain accurate TDS values ​​in unique custom solutions, the TDS conversion factor is adjustable from 0.40 to 0.80. GLP Data - Along with conductivity measurements, calibration information, including date, time, standards used, offset values, and cell constants, can be displayed on the instrument at any time by selecting the Good Laboratory Practices (GLP) display option. Recording information - The on-demand event log function allows you to save up to 500 measurement results. Saved results can be displayed on the device screen by simply pressing the "RCL" button. Data Transfer - Measurement results can be sent to a PC for analysis and storage using a USB cable and HI92000 software (sold separately). Manba: https://www.nv-lab.ru/catalog_info.php?ID=3938

Price on request
  • Conductivity Specification:
  • Conductivity range: 0.00 to 29.99 µS/cm, 30.0 to 299.9 µS/cm, 300 to 2999 µS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, to 500.0 mS/cm (absolute value of conductivity); **Conductivity Resolution: 0.01 µS/cm, 0.1 µS/cm, 1 µS/cm, 0.01 mS/cm, 0.1 mS/cm; Conductivity Accuracy (at 25 ºC): ± 1% of reading (± 0.05 µS/cm or 1 significant digit, depending on whatever is greater); Electrical conductivity calibration: automatic at 1 point using 6 standards stored in the device’s memory (84, 1413, 5000, 12880, 80000, 111800 µS/cm).
  • TDS Specification:
  • TDS range, mg/l, g/l: from 0.00 to 14.99, from 15.0 to 149.9, from 150 to 1499; from 1.50 to 14.99, from 15.0 to 100.0, up to 400.0 (absolute TDS value) ** with a conversion factor of 0.80;
  • TDS resolution, mg/l, g/l: 0.01, 0.1, 1; 0.01, 0.1;
  • TDS Accuracy (at 25 ºC): ± 1% of reading (± 0.03 mg/L or 1 significant digit, whichever is greater); TDS Conversion Factor: 0.40 to 0.80 (default value is 0.50).
  • Salinity Specification:
  • Salinity Range: 0.0 to 400.0% NaCl (seawater salinity); Salinity Resolution: 0.1% NaCl; Salinity Accuracy (at 25ºC): ± 1% of reading; Salinity Calibration: 1 point using HI7037 calibration solution (optional).
  • Temperature Specification:
  • Temperature accuracy: 0.4 °C (excluding sensor error); Temperature range: -20.0 to 120.0 °C; Temperature resolution: 0.1 °C% Temperature calibration: two points, at 0 and 50 °C; Temperature coefficient: selectable from 0.00 to 6.00%/°C (only for conductivity and TDS).
  • Additional Specification:
  • Electrode four-electrode conductivity sensor with platinum sensing elements, built-in temperature sensor and 1 m cable (included); Event log: 500 samples, on request; Automatic shutdown: after five minutes of non-use (can be disabled); Opto-isolated USB connection capability; Environment: 0 to 50 °C, relative humidity less than 95% non-condensing; Source power: DC adapter 12 V (included); Overall dimensions, mm: 235x222x109; Weight, kg: 1.3.
  • Notes:
  • * Uncompensated conductivity (or TDS) is the conductivity value (or TDS) without temperature compensation;** With temperature compensation disabled.