Mindray BeneFusion SP3 Infusion Syringe Pump
Mindray BeneFusion SP3 syringe pump. NV-Lab is the official dealer of Mindray in the Russian Federation. We guarantee the best prices and warranty service. The Mindray BeneFusion SP3 syringe pump is a compact and lightweight model with three modes: “Speed”, “Time” and “Body weight”. The device is suitable for use in an ambulance. It can connect via Wi-Fi to transfer data, and the device can also be connected to a docking station. LCD screen, monochrome (blue-white). Intuitive controls. There is a handle. The BeneFusion SP3 syringe pump can be operated with one hand. The device operates on battery power for up to 6 hours at a flow rate of 5 ml/h, optionally – 12 hours at a flow rate of 5 ml/h. The accuracy of BeneFusion SP3 is sufficient for neonatal use. There is a quick start function that eliminates delays due to friction, which is important for the treatment of children and a number of drugs. The Anti-bolus function pumps out a certain amount of fluid in the opposite direction if necessary, thereby reducing excess volume that could harm the patient. There is a log for 1500 events and a drug library. There is a configuration with the latest parameters. BeneFusion SP3 is protected from moisture and dust and can be cleaned with water. Features: Compact and lightweight pump with handle. The quick start function ensures effective and timely medication. Displaying the name of the drug and records in the archive. Continuity of infusion is ensured by the possibility of long-term battery operation. The device complies with the requirements of the EN-1789 standard, suitable for use in emergency vehicles. Manba: https://www.nv-lab.ru/catalog_info.php?ID=4906
- Dimensions, mm: 330×126×110
- Syringe volume, ml: 5, 10, 20, 30, 50 or 60
- Flow rate, ml/h: 5 ml syringe - (0.1-150),
- 10 ml syringe - (0.1-300),
- 20 ml syringe - (0.1-600),
- 30 ml syringe - (0.1-900) ml/h,
- syringe with a volume of 50 or 60 ml - (0.1-1500) ml/h
- Total volume, ml: 0.1-9999 in increments of 0.1 ml
- Set volume of infusion (VTBI), ml: 0.1-9999 in 0.1 ml increments
- Step, ml/h: 0.1-999.9 ml/h - step of 0.1
- 1000-1500 ml/h - step in 1
- Accuracy: Flow rate ≥1ml/h - accuracy ≤± 2%, flow rate <1ml/h -
- accuracy ≤± 3%
- Velocity in open vein mode (KVO): 0.1-5.0 ml/h, adjustable
- Bolus and purge rate: 0.10-1500 ml/h (depending on syringe volume)
- Blockage: Low level - 300 ± 75 mm Hg. Art. (40 kPa), average level - 525 ± 75
- mmHg Art. (70 kPa), high level - 900 ± 135 mm Hg. Art. (120 kPa)
- Drug library: 200 drugs
- Event log: 1500 events
- Weight, kg: 1.8 (including clamp)
- AC power supply, V: 100-240
- Battery type: Lithium