Mon-Fri 09:00-18:00
EXON IMPEX Modern technologies for education and business
Defibrillator-monitor DKI-N-10 “Axion”
Дефибрилляторы

Defibrillator-monitor DKI-N-10 “Axion”

Defibrillator-monitor DKI-N-10 “Axion” With a thermal printer and combined power supply it is used for electric pulse therapy of cardiac arrhythmias. The DKI-N-10 “Axion” defibrillator-monitor is used in medical hospitals, cardiology clinics, and to equip ambulance and emergency medical care teams. The defibrillator consists of two parts: a wearable part - weight 6 kg and a charger - weight 2 kg. The defibrillation pulse is bipolar trapezoidal with limited duration (BTOD), asymmetrical with the ratio of the amplitudes of the currents of negative and positive half-waves (0.5±0.1) at a load of 50 Ohms. Can be used for adults and children. Voice accompaniment of the operator’s actions and the process of operation of the device. Automatic reset of accumulated energy to the internal load 30 seconds after accumulation. Possibility of receiving and recording ECG (not included in the basic configuration). Built-in thermal printer - width no less than 57 mm. The time of continuous operation of the device in monitoring mode is at least 7 hours from replaceable batteries (one battery in the basic configuration, two in the version with ECG), when operating from a 220 V network, from the vehicle's on-board network (12-30 V) - at least 168 hours. Possibility to charge two batteries simultaneously. Display all information on LCD before and after defibrillation. Cardiac synchronized. Manual control. Manba: https://www.nv-lab.ru/catalog_info.php?ID=3885

Price on request
  • Defibrillation pulse: bipolar trapezoidal
  • Defibrillation mode: manual
  • Energy gain time 200 J: 6 s
  • Energy gain time 360 J: 10 s
  • Number of discharges of 200 J from a fully charged battery: 70
  • Number of discharges of 360 J from a fully charged battery: 40
  • Impact pulse energy for adults (additional set operation
  • energy over 200 J when working with adult electrodes): 5, 10, 25, 50, 75, 100,150, 200, 250, 300, 360 J
  • Impact pulse energy for children (blocking energy output over 150
  • J in children's mode): 5, 10, 25, 50, 75, 100, 150 J
  • Duration of positive half-wave at energies up to 250 J: 4±1 ms
  • Duration of negative half-wave at energies up to 250 J: 4±0.3 ms
  • ECG channel sensitivity: 5, 10, 20 mm/mV
  • Scan speed of waveforms on the screen: 12.5; 25; 50 mm/s
  • Heart rate measurement range: from 30 to 300 beats/min.
  • Time of continuous operation of the defibrillator in monitoring mode from
  • fully charged replacement batteries: at least 7 hours
  • Time of continuous operation of the defibrillator in monitoring mode from the network
  • DC or AC: at least 168 hours
  • AC Power: 190-250V, 50-60Hz
  • Power consumption: 250 VA
  • DC Power: 12-20V
  • Replaceable battery: 14 V, 2 Ah
  • Battery charging time: no more than 4 hours
  • Display diagonal: 5.7"
  • Display resolution: 320x240
  • Thermal printer: built-in
  • Printer paper feed speed: 12.5; 25 mm/s
  • Paper width: 57-58 mm
  • Wearable part weight: 6 kg
  • Charger weight: 2 kg
  • Charger size: 170x120x110 mm
  • Wearable part size: 380x175x270 mm

Solution selection

We will recommend a setup for a classroom, hall or laboratory

The request is saved to the database so a manager can process it later.