Mon-Fri 09:00-18:00
EXON IMPEX Modern technologies for education and business
Defibrillator AXION DKI-N-12
Дефибрилляторы

Defibrillator AXION DKI-N-12

Defibrillator AXION DKI-N-12 Intended for use in medical institutions, as well as for equipping teams of ambulances and emergency medical services. Used to provide emergency defibrillation to patients in cardiac arrest. It has a therapeutic effect on the human heart with a single biphasic truncated exponential impulse through a pair of electrodes, transthoracically. Reusable electrodes combine the ability to switch between adult and pediatric modes. Description of defibrillator DKI-N-12: The built-in software ensures that the defibrillator performs the following basic functions: setting defibrillator parameters; automatic self-test when turned on; battery condition monitoring; generating control signals for the energy storage device and the high-voltage switch; automatic setting of the initial energy level of 150 J when working with adult electrodes, 50 J and blocking the selection of energy over 100 J when working with children's electrodes; calculation of the patient's resistance based on the signal level of the resistance measurement circuit; development of commands to generate high-priority visual and audio alarms to alert the operator in the following cases: - readiness of the product for activation of the discharge by the operator; - errors in self-testing when turned on; - errors in monitoring the amount of energy given; - detection of internal fault during operation; - if the current battery charge level does not allow you to use the product; - if the patient’s resistance when trying to discharge is outside the permissible limits (15±5 - 235±15 Ohms). Benefits: The initial energy level of the adult / child modes is 150 / 50 J (set automatically). Blocks high energy levels when using baby electrodes. Possibility of power supply from a removable battery, AC mains and external power source The average time between failures of the product is at least 3000 pulses of maximum energy per load of 50 Ohms. Service life of at least 5 years Effective defibrillation using less energy due to biphasic truncated exponential pulse Equipment: defibrillator unit with electrodes; rechargeable battery Li-Ion 14.8V 4400 mAh; power adapter; power cord; carrying bag; instruction manual. Manba: https://www.nv-lab.ru/catalog_info.php?ID=8107

Price on request
  • Parameter: Value
  • Impact pulse energy, J:
  • - for adults;
  • - for children: 10, 25, 50, 100, 150, 200, 250, 300, 360; *
  • 10, 25, 50, 100**
  • Energy gain time, s, no more:
  • - 200 J;
  • - 360 J: 4;
  • 6
  • Number of energy discharges 360 J, not less:
  • - with a fully charged battery;
  • - with a fully charged battery at a temperature of 0°C;
  • - after the indication of the need to charge the battery appears: 150;
  • 20;
  • 6
  • Time to establish the operating mode, s, no more than: 3
  • Continuous operation of the device in monitoring mode from an alternating current network: 220±22 V;
  • 50 Hz
  • Time of continuous operation of the device in monitoring mode, h, not less:
  • - from a replaceable battery;
  • - from a direct current source (12-15) V: 3;
  • 168
  • Duration of half-waves at energies up to 200 J, s:
  • - positive;
  • - negative: 4±1;
  • 4±0.3
  • Power consumed from the network, VA, no more than: 210
  • Sound pressure level of alarm signals at a distance of 1 m from the front panel of the product, dB, not less: 45
  • Weight, kg, no more: 6.0
  • Overall dimensions and weight of components and accessories of the product, mm (kg), no more than:
  • - defibrillator unit with electrodes;
  • - rechargeable batteries;
  • - power adapter;
  • - carrying bags;
  • - electrode handles: 345 × 230 × 345 (4.0);
  • 135 × 143 × 40 (0.6);
  • 135 × 143 × 40 (0.3);
  • 240 × 390 × 47 (1.2);
  • 45 × 90 × 145;
  • Package dimensions (W × D × H), mm: 490 × 260 × 440
  • Length, m, not less:
  • - power cable of the power adapter;
  • - power cord: 1.8;
  • 1.8